ARMY TM 9-2805-257-14
AIR FORCE TO 38G2-103-2
NAVY NAVFAC P-8-612-14E
Table 4-2. Unit Troubleshooting Procedures (cont).
Step 6.
Check breaker points.
NOTE
The procedures to test breaker points are the same for both sets. Perform the test on
one set then repeat procedure for second set.
a.
Turn engine over so that breaker points (para. 4-30, figure 4-21) close.
b.
Connect one lead of multimeter to condenser terminal.
c.
Set multimeter to lowest resistance setting and zero meter.
d.
Connect second lead of multimeter to ground while observing meter.
If meter shows full scale deflection, go to next step. If no deflection or partial deflection
occurs, then replace breaker point (para. 4-29).
Step 7.
Check fuel flow out of fuel filter.
Service fuel filter if fuel does not flow (para. 4-13).
Step 8.
Check carburetor adjustments.
Adjust carburetor as needed (para. 4-34).
Step 9.
Deleted.
2.
ENGINE STARTS BUT FAILS TO KEEP RUNNING.
Step 1.
Remove air cleaner cup on models 2A016-1, -2 or remove air cleaner element models 2A016-3, -4.
Start Engine.
If engine stays running, service air cleaners (para. 4-20).
Step 2.
Check fuel flow out of fuel filter assembly.
If fuel flow is not present or steady, service fuel filter assembly (para. 4-13).
Step 3.
Check carburetor adjustments.
Adjust carburetor as needed (para. 4-34).
Change 2
4-5
|
|