ARMY TM 9-2805-257-14 AIR  FORCE  TO  38G2-103-2 NAVY NAVFAC P-8-612-14E 4-20. Air Cleaner (cont). b. Service.Dry . (figure 4-10) (1) (2) (3) (4) (5) (6) 4-26 Loosen  two  retaining  screws  (1),  open  air  cleaner  assembly  (2),  and  remove  element  (3). WARNING Drycleaning  solvent  PD-680  used  to  clean  parts  is  potentially  dangerous  to  personnel  and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100°F-138°F (38°C-60°C). Clean  both  halves  of  air  cleaner  assembly  using  drycleaning  solvent. Clean  element  in  detergent  and  water. Dry both halves of air cleaner assembly and element thoroughly. Position element (3) in air cleaner assembly (2) and secure with two retaining screws (1). Depress reset button (4) on service indicator (5).


 