ARMY TM 9-2805-258-14
AIR FORCE TO 38G2-89-21
NAVY NAVFAC P-8-614-14E
(4) Disconnect DC leads at battery; meter readings should be as follows:
A m p e r es
0 . 0
Volts (approx)
2
8 .5
(5) Disconnect batteries, stop engine (para. 2-10).
(6) Replace a regulator-rectifier that does not meet operation specification.
c.
Installation (figure 4-34)
(1) Install fuses (9) and fuse cover (8) and secure with screw (5), Iockwasher (6) and flat washer (7).
(2) Install regulator-rectifier (4) and secure with three assembled screws and washers (3).
(3) Connect regulator-rectifier connector (1).
Figure 4-34. Regulator-Rectifier, Removal and Installation.
4 - 75
|
|