ARMY TM 9-2805-258-14
AIR FORCE TO 38G2-89-21
NAVY NAVFAC P-8-614-14E
W A R N I N G
Drycleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or
excessive heat. Flash point of solvent is 100°F.-138°F. (38°C.-6O°C.).
(3) Clean flywheel (2) with drycleaning solvent and dry thoroughly.
(4) Inspect flywheel (2) and replace if missing teeth, cracked, chipped, or otherwise damaged.
b. Installation. (figure 5-1)
(1) Install key (3) and flywheel (2) on crankshaft (4).
(2) Install assembled bolt and washer (1) and torque bolt to 80- 83 Ib-ft (171612 - 178048 gr cm).
Figure 5-1. Flywheel, Removal and Installation.