ARMY   TM   9-2805-258-14 AIR   FORCE   TO   38G2-89-21 NAVY   NAVFAC   P-8-614-14E W A R N I N G Drycleaning   solvent   PD-680   used   to   clean   parts   is   potentially   dangerous   to   personnel   and property.   Avoid   repeated   and   prolonged   skin   contact.   Do   not   use   near   open   flame   or excessive   heat.   Flash   point   of   solvent   is   100°F.-138°F.   (38°C.-6O°C.). (3)   Clean   flywheel   (2)   with   drycleaning   solvent   and   dry   thoroughly. (4)   Inspect   flywheel   (2)   and   replace   if   missing   teeth,   cracked,   chipped,   or   otherwise   damaged. b.   Installation.  (figure    5-1) (1)   Install   key   (3)   and   flywheel   (2)   on   crankshaft   (4). (2)   Install   assembled   bolt   and   washer   (1)   and   torque   bolt   to   80-   83   Ib-ft   (171612   -   178048   gr   cm). Figure  5-1.  Flywheel,   Removal   and   Installation. 5 -5


 