ARMY   TM   9-2805-258-14 AIR   FORCE   TO   38G2-89-21 NAVY   NAVFAC   P-8-614-14E 4-14.  Air   Cleaner   Element   (cont). b. Replacement    ( f i g u r e    4 - 3 ) (1)   Loosen   clamp   (1)   and   remove   hose   (2)   from   air   cleaner   body   (3). (2)   Unsnap   two   clips   (4)   and   remove   body   (3). (3)   Remove   element   (5)   from   body   (3). (4)   Remove   restriction   indicator   (6). W A R N I N G Drycleaning   solvent   PD-680   used   to   clean   parts   is   potentially   dangerous   to   personnel   and property.   Avoid   repeated   and   prolonged   skin   contact.   Do   not   use   near   open   flame   or excessive   heat.   Flash   point   of   solvent   is   100°F.-138°F.   (38°C.-60°C.). (5)   Clean   body   (3)   and   head   (7)   with   drycleaning   solvent,   and   dry   thoroughly. (6)   Install   element   (5)   in   body   (3). (7)   Install   body   (3)   and   secure   with   two   clips   (4). (8)   Install   restriction   indicator   (6). (9)   Install   hose   (2)   and   tighten   clamp   (1). (10)   Depress   reset   button   (8)   on   restriction   indicator   (6). 4 - 12


 