ARMY TM 9-2805-258-14
AIR FORCE TO 38G2-89-21
NAVY NAVFAC P-8-614-14E
4-18. Breather Tube.
This task covers:
a. Removal
b. Inspection
c. Installation
INITIAL SETUP
Tools
Equipment Condition
GeneraI Mechanics Tool Kit (Item 1, Appendix B)
Air cleaner elbow removed (para. 4-17).
Materials/Parts
Rags, Wiping (Item 7, Appendix D)
Solvent, Drycleaning (Item 8, Appendix D)
Gasket, Air Breather Cover (NSN 2805-00-937-0943)
a. Removal. (figure 4-7)
Remove three screws (1) and washers (2) and remove breather tube (3) and gasket (4).
b. I n s p e c t i o n . (figure 4-7)
W A R N I NG
Drycleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
properly. Avoid repeated and prolonged skin contact. Do not use near open flame or
excessive heat. Flash point of solvent is 100°F.-138°F. (38°C.-6O°C.).
(1) Clean breather tube in drycleaning solvent, and dry thoroughly.
(2) Ensure there are no obstructions in breather tube (3).
c.
/nsta//ation. (figure 4-7)
(1) Ensure gasket surfaces are clean and old gasket material is removed.
(2) Install breather tube (3) and gasket (4) and secure with three screws (1) and washers (2).
4 - 20
|
|