ARMY   TM   9-2805-258-14 AIR   FORCE   TO   38G2-89-21 NAVY   NAVFAC   P-8-614-14E 4-28.  Low   Oil   Pressure   Shutdown   Switch   and   “T”   Connector. This   task   covers: a.    Removal b.    installation c.   Test INITIAL    SETUP Tools Equipment   Condition General   Mechanic’s   Tool   Kit   (Item   1,   Appendix   B) Top   cover   removed   (para.   4-21). Multimeter    (NSN    6625-01-139-2512) (Item   2,   Appendix   B) Materials/Parts Rags,   Wiping   (Item   7,   Appendix   D) Solvent,   Drycleaning   (Item   8,   Appendix   D) a.  l   (figure   4-19) (1) (2) (3) (4) (5) (6) (7) (8) Loosen   connector   nuts   (1)   and   tag   and   remove   high   tension   cables   (2). Tag   and   remove   wiring   from   low   oil   pressure   shutdown   switch   (3). Remove    switch    (3). Loosen   connector   nut   (4)   and   remove   oil   line   (5). Remove   “T”   connector   (6) W A R N I NG Drycleaning   solvent   PD-680   used   to   clean   parts   is   potentially   dangerous   to   personnel   and property.   Avoid   repeated   and   prolonged   skin   contact.   Do   not   use   near   open   flame   or excessive   heat.   Flash   point   of   solvent   is   100°F.-138°F.   (38°C.-6O°C.). Clean   switch   (3)   with   drycleaning   solvent,   and   dry   thoroughly. inspect   switch   (3)   and   replace   if   damaged. Inspect   “T”   connector   (6)   and   replace   if   damaged. b. /nsta//ation.(figure 4-19) (1)   Install   “T”   connector   (6). (2)   Install   oil   line   (5)   and   tighten   fitting   nut   (4). (3)   Install   switch   (3). 4 - 4 4


 