ARMY TM 9-2805-262-14
AIR FORCE TO 38G2-90-1
NAVY NAVFAC P-8-613-14E
f. Dimensions and Weight Model 4A032-4.
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...27.25 in. (69.21 cm)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24.25 in. (61.59 cm)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 18in. (45.72 cm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 110 lbs (49.5 kg)
1-12. Differences Between Models. All four models of the Military Standard are similar except for the
following differences:
a.
b.
c.
d.
e.
f.
Models 4A032-2, -3, -4 have dry element air cleaners with service indicators.
Models 4A032-1 (serial nos. G000001 through G000500) is equipped with engine stop button.
Model 4A032-1 (serial nos. G001001 through G004004), -2 -3, and -4 are equipped with an ignition switch.
Models 4A032-1 and -2 are equipped with a breaker point ignition.
Model 4A032-3, -4 is equipped with breakerless ignition.
Models 4A032-1 (serial nos. G001001 through G004004), -2,-3, and -4 are equipped with a throttle control.
1-13. Safety, Care, and Handling. Observe all WARNINGS, CAUTIONS and NOTES in this manual. This
equipment can be extremely dangerous if these instructions are not followed.
Section Ill. PRINCIPLE OF OPERATION
1-14. Principles of Operation.
a. General. The 6 HP Military Standard engine is a four cycle four cylinder, horizontally apposed, air cooled,
gasoline powered internal combustion engine. The engine develops its full rated capacity at a governed 3600
r.p.m.
b. Simplified Principles of Operation. A starter rope pulley, provides a means to connect the starter rope for
pull starting the engine. An inline fuel filter cleans the fuel supplied to the engine. The filter comes equipped with
a fuel cutoff valve, that when closed, stops fuel flow to the engine. The engine comes equipped with dry element
air cleaner. On models 4A032-2, -3, and -4 the air cleaner comes equipped with a service indicator. The service
indicator signals when the element requires cleaning. The inlet temperature control varies the amount of
unheated air entering the air cleaner. On model 4A032-1 (serial nos. G000001 through G000500) a stop button is
used to terminate engine operation. On models 4A032-1 (serial nos. G001001 through G004004), -2, -3, and -4a
two position ignition switch is used. When the switch is in the RUN position the engine can be started. Setting the
switch to OFF terminates engine operation
1-8
|
|