Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (650 AMPERE)
0051 00
REMOVAL (Continued)
2. Disconnect ground straps (7).
a. Honeywell: Remove protective coating, screw (2), flat washer (3), and nut (4) from bus
bar (8) to remove ground straps (7).
4
3
7
8
2
b. Ormat: Remove protective coating, screw (2), flat washer (3), and nut (4) from
bus bar (9) to remove ground straps (7).
4
3
7
2
9
WP 0051 00-3

 