Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (650 AMPERE)
0051 00
INSTALLATION (Continued)
7. Engage generator (28) drive shaft (32).
a. Slide generator (28) slowly towards adapter plate (31) until drive shaft (32) engages.
b. It may be necessary to turn drive shaft for proper engagement. A long screwdriver may be
used for this purpose.
28
32
30
31
8. Secure generator (28) to adapter plate (31).
a. Be sure generator (28) is tight against adapter plate (31). Assure that inlet fitting (14) is at
the 6 o'clock position (+/- 6) for the Ormat generator. This fitting is the same for the
Honeywell, but it is not critical that it be at the 6 o'clock position.
b. Position V-band clamp (30) over mating flanges of generator (28) and adapter plate (31).
c. Tighten V-band clamp (30) to 60-65 inch-pounds (7 Nm). Tap clamp lightly with plastic
hammer as it is being tightened.
30
31
28
14
WP 0051 00-11

 