SIGNAL WIRING HARNESS REPLACEMENT (2CA) (PN 12254376, 12354385) 0057 00
INSTALLATION (Continued)
6. Install harness to top-mounted low voltage protection module (LVPM).
a. Remove nut (73) and lock washer (74) from starter positive lug.
b. Install LVPM module wire (75) to starter positive lug with existing nut (73) and lock
washer (74).
c. Install LVPM lead (78) with machine screw (76) and lock washer (77).
75
78
76, 77
73, 74
d. Install loop clamp (72) onto cable.
e. Install screw (70) with new lock washer (71) (item 93, WP 0175).
72
70, 71
WP 0057 00-19

 