TM 9-2815-220-24
STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT,
0061 00
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
REMOVAL (Continued)
NOTE
For smoke generation systems with dual-solenoid configuration,
harness removal instructions are covered in steps 7 and 8.
For smoke generation systems with single-solenoid configuration,
harness removal instructions are covered in steps 9 and 10.
8. Remove smoke generator lead (33) on models with dual-solenoid smoke generation systems.
a. Remove self-locking nut (37) and loop clamp (38) for dust detector and smoke generator
leads. Discard self-locking nut.
b. Remove connectors at smoke generator solenoids (39).
c. Cut and remove tie wraps (40) as needed.
37
40
33
38
39