STARTER/ SMOKE GENERATOR/ DUST DETECTOR WIRING HARNESS REPLACEMENT,
0061 00
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
INSTALLATION (Continued)
NOTE
Engine models with 300 ampere electrical systems have only one
starter electrical ground lead (5).
11. Install starter ground harnesses (4) and straps (5).
a. Remove nut (6) from starter ground terminal post (8).
b. Install two starter ground harness (4) and two ground straps (5).
c. Reinstall nut (6) and lock washer (7).
d. Install ground straps (5) at starter mounting base (11) using screw (9)
with two flat washers (10).
e. Install tie wraps (12) (item 81, WP 0175) as necessary.
12. Install starter positive harness (13).
a.  Remove nut (14) from starter positive post (17).
b. Install two starter harness (13), and starter low voltage protection
module harness terminal (16).
c. Reinstall nut (14) and lock washer (15) onto starter positive post (17).
d. Install starter low voltage protection module harness using machine screw (18).
e. Install tie wraps (12) (item 81, WP 0175) as necessary.
14, 15
17
16
8
6, 7
18
13
12
11
5
9, 10
4