STARTER SOLENOID HARNESS REPLACEMENT (2DR) (PN 11671792)
0062 00
REMOVAL (Continued)
1. Remove starter wiring harness (continued).
e. Disconnect starter low voltage protection module cable connector (13).
f. Remove nut (14) with lock washer (15) from starter ground terminal post (16). Remove
ground cables (4). Reinstall nut (14) and lock washer (15) for safe keeping.
g. Remove screw (18), two flat washers (19) and lock washer (20)
securing ground cable (17). Discard star washer.
h. Remove low voltage protection module connection at starter solenoid (21).
i. Remove nut (22) with lock washer (23) from starter positive terminal post (24). Remove
positive cables (10). Reinstall nut (22) and lock washer (23) for safe keeping.
j. Cut and remove tie wraps (25) on starter cables as required.
21
24
14, 15
16
25
13
22, 23, 24
17
10
4
21
25
20
14, 15
17
22, 23, 24
18
16
10
17
19