TURBOSUPERCHARGER DUST DETECTOR SYSTEM REPLACEMENT
0082 00
REMOVAL (Continued)
1. Remove pressure switch (1) (Continued).
e. Remove two cap screws (12) with lock washers (13) to separate pressure switch (1) from
bracket (11). Discard lock washer.
f. Remove two adapter fittings (14, 15) with O-rings (16). Discard O-rings.
14
1
16
11
15
16
12, 13
12, 13