TURBOSUPERCHARGER DUST DETECTOR SYSTEM REPLACEMENT
0082 00
INSTALLATION
1. Install fittings.
a. Install two adapter fittings (14, 15) with new O-rings (16) (item 75, WP 0175).
2. Install pressure switch (1) onto bracket (11).
a. Position pressure switch (1) onto bracket (11) and secure using two cap screws (12) with
new lock washers (13) (item 92, WP 0175).
14
1
16
11
15
16
12, 13
12, 13