SMOKE GENERATION SYSTEM REPLACEMENT
0094 00
INSTALLATION (Continued)
2. Assemble solenoid bracket components.
a. Install pipe nipple (29) into one solenoid (20).
b. Install second solenoid (20) onto pipe nipple (29).
c. Place solenoid bracket (25) into a vice.
d. Install four screws (27) with flat washers (28) to secure solenoids (20)
to bracket (25).
e. Install elbow (19) into solenoid (20).
f. Install adapter (26) into elbow (19).
g. Install elbow (22) into solenoid (20).
NOTE
Check position of electrical connectors on new solenoid valves. Hold
the valve with the inlet port marked "IN" to the right and the outlet
port marked "OUT" to the left. The electrical connectors must be
approximately 45 degrees from the inlet ports and pointing toward
you.
If the connectors must be repositioned, place the valves in a soft jawed
vise. Loosen the acorn nut on top of the valves. Rotate the connectors
and tighten acorn nuts to 50 inch-pounds (5.65 Nm). Remove and
discard protective covers and felt filtering disks (if present) from inlet
and outlet ports.
20
22
29
19
26
28
(four places)
27
(four places)
25
WP 0094 00-11
|
||