Tweet |
Custom Search
|
|
|
||
TM 9-2815-220-24
INTAKE MANIFOLD ASSEMBLY REPLACE/REPAIR
0108 00
REPAIR
1. Replace stripped, bent, or otherwise damaged studs (36 through 40).
a. Refer to Work Package 0028 for procedure and to the following table for height settings.
Location
Setting Height
Quantity
Stud Size and Length
Required
36
1-3/8
8
5/16-24(25/32) x 5/16-24(19/32) x 1-7/16
37
13/16
16
5/16-18 (9/16) X 5/16-24 (11/16) X 1-3/8
38
1
12
5/16-18 (3/4) X 5/16-24 (23/32) X 1-5/8
39
25/32
12
5/16-18 (11/16) X 5/16-24 (9/16)X 1-5/16
40
23/32
24
5/16-18 (11/16) x 5/16-24 (9/16)x 1-5/16
36
39
38
37
38
40
37
40
WP 0108 00-5
|
||