INSPECTION (Continued)
12. Replace any loose or damaged dowel pins
45
(44), tubes (46), or sleeve spacer (45). Refer
44
44
46 (4 places)
13. Replace damaged, bent, or stripped studs (47,48,49,50 and 51).
a. Refer to WP 0028 for standard procedure and to the following table for stud size and
setting height.
Location
Setting Height
Quantity
Stud Size and Length
Required
47
7/8 (22.2250 mm)
3
5/16-18(3/4) X 5/16-24(19/32) X 1-1/2
47
3/4 (19.0500 mm)
4
3/8-16(13/16 X 3/8-24(3/4) X 1-7/8
49
1 (25.4000 mm)
2
5/16-18(3/4) X 5/16-24(19/32) X 1-1/2
50
25/32(19.8438 mm)
8
5/16-18(3/4) X 5/16-24(19/32) X 1-7/16
51
29/32 (23.0188 mm)
4
5/16-18(3/4) X 5/16-24(19/32) X 1-9/16
47
50
51
49
48 (4 places)
50
WP 0169 00-14

 