LOW VOLTAGE PROTECTION MODULE MOUNTING BRACKET
REPLACEMENT
0171 00
CLEANING
1. See Work Package 0028 for Standard Cleaning Procedures.
INSPECTION
All parts must be inspected with care. Replace part if damage or wear exceeds allowable
limits.
1. See Work Package 0028 for Standard Inspection Procedures.
INSTALLATION
1. Install starter relay mounting bracket (1).
a. Apply a small amount of lubricant (item 23, WP 0173) to four bolts (2), (4).
b. Position LVPM bracket (1).
c. Install wiring harness and clamp (5), secure bracket with two bolts (4), and two new lock
washers (3) (item 86, WP 0175).
d. Secure two bolts (2) with two new lock washers (3) (item 86, WP 0175).
e. Tighten bolts (2) and (4) to 156 to 180 inch-pounds (18-20 Nm).
5
3
1
4
3
2
END OF WORK PACKAGE
WP 0171 00-2

 