Custom Search
 
  
 
TM 9-2815-226-34-1
3-11. INSPECT LINERS
a. Using magnetic particle method, inspect liner just under top flange, bottom of liner, and above top seal ring
groove for cracks. Discard cracked liners.
b. Check exterior of liner for excessive corrosion or erosion and pits 1/16 in. (1.59 mm) deep or more. Discard if
defective.
c. Check liners for dents, pitting, or fretting on underside of top flange. Discard if defective.
d. Check liners for wear with dial bore gage. Discard liner if inside diameter exceeds 5.505 in. (139. 827 mm).
3-116


 