CAUTION
UNDER NO CIRCUMSTANCES SHOULD AN ATTEMPT BE MADE TO SCRAPE, LAP,
OR FILE BEARING HALVES TO INCREASE OIL CLEARANCE.  RAPID ENGINE
FAILURE MAY RESULT.
d. Total worn maximum clearance should not vary more than 0.002 in.
(0.050 mm) between adjacent main
e. If crankshaft is regr ound to accept undersize bearings, new undersize bearings must be used. Bearings are
available in 0.010, 0.020, 0.030, and 0.040 in. (0.254, 0.508, 0.762, and 1.016 mm) undersizes.
Section VII. CONNECTING ROD REPAIR
3-16. CLEAN CONNECTING ROD
WARNING
P-D-680 SOLVENT IS POTENTIALLY DANGEROUS.  AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN.  KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
a. Submerge rods in cleaning solvent for two hours.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA).  USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
b. Remove rods and wipe clean. Dry with compressed air.
3-127


 