(16) If leakage is determined to be at valve-to-seat sealing area, regrind seat insert and reface valve.
(17) Detach power plug from wall outlet.
(18) Wipe entire head clean.
Section XII. ROCKER LEVER HOUSING ASSEMBLY REPAIR
3-33. DISASSEMBLE ROCKER LEVER HOUSING ASSEMBLY AND LEVERS.
a. Clean rocker lever housing assembly.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30
PSI (207 KPA).
USE ONLY WITH EFFECTIVE CHIP GUARDING AND
PERSONAL PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
P-D-680 SOLVENT IS POTENTIALLY DANGEROUS.  AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN. KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
(1) Clean housing in solvent. Dry with compressed-air.
CAUTION
TAKE CARE NOT TO GOUGE OR GROOVE SEALING SURFACES. CAN RESULT IN
OIL LEAKAGE.
NOTE
Housings are made of steel or aluminum.
(2) Carefully scrape gasket material from sealing surfaces. Wipe with cloth dampened with solvent.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA).  USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
(3) Dry with compressed air.
3-198


 