TM 9-2815-226-34-1
Section XIV. CAM FOLLOWER HOUSING ASSEMBLY REPAIR
3-38. DISASSEMBLE CAM FOLLOWER HOUSING ASSEMBLY
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA). USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
P-D-680 SOLVENT IS POTENTIALLY DANGEROUS. AVOID PROLONGED OR
REPEATED CONTACT WITH SKIN. KEEP AWAY FROM FLAME OR EXCESSIVE
HEAT.
a. Clean housing and cam follower assembly with solvent. Dry with compressed air.
b. Disassemble cam follower housing assembly.
NOTE
Each housing has two cam follower shafts.
(1) Remove two lockscrews securing shafts to housing.
(2) With sharp pointed prick punch, punch hole in center of housing expansion cup plug.
3-212