WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA). USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
(c) Clean out tapped hole with compressed air.
(d) Install new drain plug with new copper gasket.
(e) Torque plug to 60 - 70 ft lbs (81 - 95 Nm).
(3) Replace screen if defective.
(a) Remove capscrews and washers securing oil suction tube adapter to oil pan.
(b) Remove oil suction tube adapter and discard gasket.
(c) Remove capscrews and lockwashers securing screen to pan.
(d) Remove screen.
(e) Wipe screen mounting surface clean in pan.
(f) Install new screen.
(g) Secure with capscrews and lockwashers.
(h) Using new gasket, secure oil suction tube adapter to oil pan with capscrews and washers.