TM 9-2815-226-34-2
Section XXIV. EXHAUST MANIFOLD REPAIR
3-63. INSPECT EXHAUST MANIFOLDS
a. Separate manifolds.
WARNING
COMPRESSED AIR USED FOR CLEANING PURPOSES WILL NOT EXCEED 30 PSI
(207 KPA). USE ONLY WITH EFFECTIVE CHIP GUARDING AND PERSONAL
PROTECTIVE EQUIPMENT (GOGGLES, SHIELD, GLOVES, ETC.).
WEAR PROTECTIVE CLOTHING AND GOGGLES WHILE STEAM CLEANING TO
PREVENT POSSIBLE PERSONAL INJURY.
b. Steam clean manifolds and dry with compressed air.
c. Inspect manifolds for cracks and distortions.
d. Discard defective parts.
e. Check center manifold turbocharger mounting studs for corrosion, thread distortion, and bends.
f. Mark defective studs for replacement.
3-253
|
||