(4) Tighten knurled lock pin to lock injector in place.
(5) Install 3375397 injector plunger extension in top of injector plunger and tighten knurled knob to lock in
place.
(6) Insert 3375396 link into plunger extension.
(7) Install entire assembly into injector guide, link end first. Secure in place with locking lever.
NOTE
Supply (white) hose attaches to fitting located nearest the injector cup.
(8) Install supply and drain hoses to fittings on adapter pot.