Custom Search
 
  
 
TM 9-2815-226-34-2
e. Pull fixture handle down to bottom plunger in its cup and set dial indicator (extension in contact with surface of
plunger coupling) to zero.
f. Release plunger slowly and observe travel required until plunger spring washer contacts injector top-stop.
3-285


 