Custom Search
 
  
 
TM 9-2815-226-34-2
(29) Connect flexible hose from leak test connector to no. 1 accumulator.
(30) Install T-fitting into gear pump bleed drain fitting.
(31) Connect leakage accumulator hose from auxiliary return to T-fitting.
(32) Install hydraulic air signal attenuator (ASA) valve into top of fuel pump main housing.
(33) Connect flexible hose from ASA valve to T-fitting.
(34) Remove governor spring pack cover plug.
(35) Install 3375981 fuel pump idle adjusting tool in governor spring pack housing.
3-343


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business