(5) When proper fuel pressure is reached, tighten adjustment screw locknut.
(6) When all calibration checks have been completed, slow down test stand to minimum rpm, then actuate stand
STOP button.
o. Remove fuel pump from test stand.
(1) Remove AFC adjusting tool from pump.
(2) Install AFC cover plate, with its flow valve installed, on fuel pump main housing.
NOTE
Bottom capscrew should have a lockwire hole drilled through its head.
(3) Secure cover plate with capscrews.
(4) Torque capscrews to 30 - 45 in. lbs (3.39 - 5.09 Nm).
(5) Disconnect all hoses from fuel pump assembly and test stand.
3-371


 