TM 9-2815-226-34-2
CAUTION
DO NOT PRIME LUBE SYSTEM FROM REMOTE BYPASS FILTER CONNECTOR ON
OIL COOLER ABOVE FILTER.
IMPROPER PRIMING MAY RESULT,
ACCELERATING ENGINE MOVING PARTS WEAR AND FAILURE.
(5)
Remove pipe plug from left side of cylinder block.
(6)
Connect a hand or mot or-driven priming pump line from source of clean lubricating oil to plug port
in housing.
(7)
Prime until a 30 psi (207 kPa) maximum pressure is obtained.
(8)
Manually close fuel pump shut-off valve to prevent engine start.
CAUTION
DO NOT CRANK ENGINE CONTINUOUSLY FOR MORE THAN 30 SECONDS.
EXCESSIVE CRANKING CAN OVERHEAT STARTER CAUSING POSSIBLE
INTERNAL DAMAGE.
(9)
Crank engine for minimum of 15 seconds while maintaining external oil pressure at minimum of
15 psi (103 kPa).
(10)
Stop cranking.
(11)
Remove external priming line.
3-465