Custom Search
 
  
 
TM  9-2815-237-34 2-16. CYLINDER BLOCK REPAIR (Cont’d) WARNING Compressed  air  used  for  cleaning  purposes  will  not  exceed  30  psi (207  kPa).  Use  only  with  effective  chip  guarding  and  personal protective   equipment   (goggles/shield,   gloves,   etc.). d. Blow all dirt and cleaning solution from capscrew holes and oil passages with compressed air. e.  Refer  to  para.  2-9  for  additional  cleaning  instructions. f.  Coat  all  cylinder  bores,  lifter  bores,  and  machined  surfaces  with  OE/HDO. g. Apply pipe sealing compound to six protective dust caps (3) and all plugs (4) and install in cylinder  block  (1). 2-41


 