TM 9--2815--247--34
0049 00--6
METERING PUMP THROTTLE LINKAGE AND ASSOCIATED PARTS REPAIR
-- CONTINUED
0049 00
Installation
1. Install assembled rotating eye bracket (26), angle bracket (25) and spring (29) as a unit on fan housing (27) and
secure with three new self--locking nuts (24).
Figure 48
24
27
25
26
29
2. Inspection and repair of governor control rod assembly (21) (WP 0050 00).
3. Attach governor control rod assembly (21) to bell crank (15) using machine bolt (22) and a new self--locking nut
(23).
4. Attach governor control rod assembly (21) to metering pump (12) using machine bolt (19), and a new self--locking
nut (20).
5. Inspection and repair of control rod assembly (5) (WP 0051 00).
6. Attach control rod assembly (5) to bell crank (15) using machine bolt (16), flat washer (18), and a new self--locking
nut (17).
7. Attach rigid connecting link (1) to metering pump (12) using flat washer (14) and a new cotter pin (13).
8. Install angle bracket (10) using two screws (9) on metering pump (12) and attach spring (11) to metering pump
(12) and angle bracket (10).
Figure 48
1
20
19
17
18
16
5
15
10
11
9
13
14
12
12
12
21
22
23
|
|