TM 9--2815--247--34 0071 00--4 LUBRICATING NOZZLE ASSEMBLY REPAIR -- CONTINUED 0071 00 Adjust 1.   Plug off all nozzles (6) where cylinders are removed except one, with hose (8) and hose clamps (9). Figure 8 6 9 8 2.   Remove pipe plug (10) and install improvised tool (11) to block off oil passage to the fan towers. 3.   Remove pipe plug (12) and connect a 60 psi (413.7 kpa) oil supply to this passage. NOTE Oil supply should be at least three gallons of SAE--10 oil with pump or pressurized container and a pressure gauge. 4.   Install target fixture (13) on cylinder pins (14) and secure with knob (15). 5.   Operate oil supply at 60 psi (413.7 kpa) and, using bending tool (16), adjust nozzle (6) to provide accurate oil stream to center of target (17). Figure 74 11 13 17 14 15 16 16 6 10 12


 