Custom Search
 
  
 
TM 9--2815--247--34 0092 00--2 HEATER FUEL FILTER MOUNTING BRACKET REPLACEMENT -- CONTINUED 0092 00 Installation 1.   Install filter mounting bracket (3) on damper housing (4). 2.   Apply a small amount of lubricant to studs (5) on damper housing (4). 3.   Install two new self--locking nuts (1) and two flat washers (2). 4.   Tighten two self--locking nuts (1) to 225--250 lb--in. (25--28 NSm). Figure 42 1 2 3 4 5 NOTE FOLLOW--ON MAINTENANCE: Install flame heater solenoid valve (TM 9--2350--292--20) Install flame heater filter (TM 9--2350--292--20) END OF TASK


 