Custom Search
 
  
 
TM 9--2815--247--34 0096 00--14 MECHANICAL DRIVE HOUSING AND ASSOCIATED PARTS (FAN TOWER, DAMPER END) REPAIR -- CONTINUED 0096 00 Repair 1.   Replace any loose or damaged pins (44), tubes (46), or sleeve spacer (45). Refer to WP 0012 00. 2.   Replace damaged, bent, or stripped studs (64, 65, 66, 67 and 68). Refer to WP 0012 00. REF NO. SETTING HEIGHT NO. REQUIRED STUD SIZE AND LENGTH 64 7/8 (22.2250 mm) 3 5/16--18(3/4) X 5/16--24(19/32) X 1--1/2 65 3/4 (19.0500 mm) 4 3/8--16(13/16 X 3/8--24(3/4) X 1--7/8 66 1 (25.4000 mm) 2 5/16--18(3/4) X 5/16--24(19/32) X 1--1/2 67 25/32(19.8438 mm) 8 5/16--18(3/4) X 5/16--24(19/32) X 1--7/16 68 29/32 (23.0188 mm) 4 5/16--18(3/4) X 5/16--24(19/32) X 1--9/16 Figure 54 44 44 46 46 65 46 45 65 65 65 64 66 68 67 67 67 67 68 46


 