TM 9--2815--247--34
0096 00--14
MECHANICAL DRIVE HOUSING AND ASSOCIATED PARTS (FAN TOWER,
DAMPER END) REPAIR -- CONTINUED
0096 00
Repair
1. Replace any loose or damaged pins (44), tubes (46), or sleeve spacer (45). Refer to WP 0012 00.
2. Replace damaged, bent, or stripped studs (64, 65, 66, 67 and 68). Refer to WP 0012 00.
REF NO.
SETTING HEIGHT
NO. REQUIRED
STUD SIZE AND LENGTH
64
7/8 (22.2250 mm)
3
5/16--18(3/4) X 5/16--24(19/32) X 1--1/2
65
3/4 (19.0500 mm)
4
3/8--16(13/16 X 3/8--24(3/4) X 1--7/8
66
1 (25.4000 mm)
2
5/16--18(3/4) X 5/16--24(19/32) X 1--1/2
67
25/32(19.8438 mm)
8
5/16--18(3/4) X 5/16--24(19/32) X 1--7/16
68
29/32 (23.0188 mm)
4
5/16--18(3/4) X 5/16--24(19/32) X 1--9/16
Figure 54
44
44
46
46
65
46
45
65
65
65
64
66
68
67
67
67
67
68
46
|
|