TM 9--2815--247--34
0096 00--23
MECHANICAL DRIVE HOUSING AND ASSOCIATED PARTS (FAN TOWER,
DAMPER END) REPAIR -- CONTINUED
0096 00
Installation -- Continued
7. Secure fan drive housing assembly (11) to base using nine new self--locking nuts (13) and nine flat washers (14).
NOTE
A new self--locking nut will be installed on remaining stud
(15) when the fire extinguisher tube is installed.
8. Tighten nine self--locking nuts (13) to 275--300 lb--in (31--34 NSm).
9. Tighten two screws (17) to 275--300 lb--in (31--34 NSm).
10. Install new locking wire (16) securing two screws (17).
Figure 54
13
14
16
11
15
17
17
|
|