TM 9--2815--247--34 0015 00--7 INTAKE AND EXHAUST VALVE AND METERING PUMP TIMING -- CONTINUED 0015 00 Test -- Continued 13. Turn flywheel until cylinder 6L valves are closed and camshaft lobes are in the position shown. Figure 10 VALVE ROCKER ROLLERS CAMSHAFT PISTON (T.D.C.) INTAKE VALVE (CLOSED) CAMSHAFT LOBES EXHAUST VALVE (CLOSED) 14. Using thickness gauge blade (15), set cylinder 6L intake valve clearance to 0.100 inch (2.5 mm) by turning the adjusting screw (16) clockwise to decrease the clearance or counterclockwise to increase the clearance. 15. Check position of valve adjusting screw pad (17) to make sure seat is flat on valve stem. 16. Torque adjusting screw nut (18) to 200--225 lb--in (22.6--25.4 NSm). Figure 9 18 17 16 15


 