Custom Search
 
  
 
ARMY TM 9-2815-252-24 AIR FORCE TO 38G1-92-2 FIGURE 3-24.  Solenoid Terminals 3-24.4.  Cleaning and Inspection. Warning Cleaning solvent Is flammable and toxic to eyes, skin, and respiratory tract.  Skin/eye protection required.  Avoid repeated/prolonged contact.  Good general ventilation Is normally adequate. CAUTION Do  not  clean  overrunning  clutch  In  solvent  or  other  cleaning  solution.    Washing  clutch  will remove grease which may result in damage to the clutch. a.  Wipe all metallic parts with a cleaning cloth (TX- 1250) that has been slightly dampened with solvent (P-D- 680). b.  Inspect all parts for damaged threads, cracks, distortion, or other visible damage. Warning Compressed air used for cleaning can create airborne particles that may enter the eyes.  Pressure will not exceed 30 psig (207 kPa).  Eye protection required. c.  Inspect armature commutator.  If commutator is dirty or discolored, clean with abrasive paper (#400).  Use compressed air to blow sand out from between commutator segments. d.  Clean around brushes and holders by wiping off all brush dust and dirt.  If brushes are shorter than 0.433 in. (11.0 mm) they should be replaced. e.  Check for free movement of brushes.  Brushes should move freely when placed in brush holders.  Replace brush springs if weak or worn. 3-49


 