ARMY  TM  9-2815-254-24 AIR FORCE TO 38G1-84-2 c.  Teat  field  ceil. (1) Check for continuity between brushes with a multimeter. (2)   If there is no continuity indicated, field coil is open and field coil frame must be replaced. (3)   Check for continuity between field coil frame and brushes. (4)   If continuity is indicated, field coil is grounded and field coil frame must be replaced. d.   Test   solenoid. (1)   Check for continuity between solenoid terminals M and B with a multimeter. Refer to FIGURE 3-48. (2) No continuity should be indicated when solenoid plunger is in normal (out) position. (3) Push solenoid plunger in and note multimeter. Multimeter should indicate continuity. If no continuity is indicated, solenoid must be replaced. 3-23.4.  Cleaning  and  Inspection. Cleaning solvent is flammable and toxic to eyes, akin, and respiratory tract.  Skin/eye  protection  required.  Avoid  repeated/prolonged  contact. Good general ventilation is normally adequate. Compressed  air  used  for  cleaning  can  create  airborne  particles  that may enter the eyes. Pressure will not exceed 30 psig (207 kPa). Eye protection  required. 3-90


 