ARMY TM 9-2815-254-24
AIR FORCE TO 38G1-94-2
FIGURE 3-16. Removing Plunger Barrel
al.
If necessary, remove and retain two bleed screws (40), two gaskets (41), three studs (42), and adapter (43).
3-11.2.3.
Feed Pump.
Use vise jaw covers to avoid damage to feed pump housing (10, FIG-
URE 3-7).
a.
Clamp feed pump in a vise with priming pump (20) up.
b.
Unscrew and remove priming pump (20) and preformed packing (21). Discard preformed packing.
c.
Unscrew and remove adapter (22) and preformed packing (23). Discard preformed packing.
d.
Remove both check valves (24) and springs (25).
e.
Position pump housing in vise so plug (26) faces upward.
N O T E
Tap plug (26) with a hammer to aid in loosening it.
3-41
|
|