ARMY TM 9-2815-254-24 AIR FORCE TO 38G1-94-2 FIGURE   3-33.   Priming   Pump   Test aj. Perform feed pump capacity test as follows: N O T E Feed  pump  can  be  tested  for  capacity  while  installed  on  engine.  Discon- nect discharge hose and insert in measuring container. Crank engine for  15  seconds.  Supply  rate  should  be  at  least  60  cc.  Replace  feed pump if it fails to meet supply rate. (1)   Pump should be piped as in step ah, except place end of discharge pipe in a measuring cylinder, refer to FIGURE 3-34. (2) Operate injection pump at speeds specified in TABLE 3-2 and check for corresponding supply rate. 3-60


 