ARMY TM 9-2815-255-24
AIR FORCE TO 38G1-95-2
MARINE CORPS TM 2815-24/4
c.
Remove two capscrews (1), and lockwashers (2) securing cover (3) to housing (8); remove cover (3) and gasket
(4). Discard gasket (4) and lockwashers (2).
d.
Lift thermostat (5) from housing (8).
e.
Loosen two hose clamps (9) and remove by-pass hose (10) from housing adapter (11) and water pump housing.
NOTE
If installed, remove temperature sending unit.
f.
Remove two capscrews (6) and lockwashers (7) securing housing (8); remove housing (8) and gasket (12).
Discard gasket (12) and lockwashers (7).
3-21
|
|