ARMY TM 9-2815-256-24
AIR FORCE TO 38G1-96-2
MARINE CORPS TM 2815-24/5P
FIGURE 3-98. Installing Metering Valve
aw. Pull back governor linkage hook (46, FIGURE 3-64), stretching spring (47) just enough to assemble hook
correctly to fork on governor arm (44). Position opposite end of hook (46) over pin on arm of metering valve
(45), refer to FIGURE 3-99. Check all governor parts for freedom of movement.
FIGURE 3-99. Installing Governor Linkage
ax. Ensure bushing (10, FIGURE 3-67) on control rod assembly (5) is against control spring guide on control rod.
ay. If removed, thread spring (42, FIGURE 3-64) on tab of governor arm (44).
az. Thread piston assembly (43) on loose end of spring (42).
ba. From inside pump housing (84), install control rod assembly through threaded hole.
NOTE
Tighten 70 to 80 in-lbs (8 to 9 Nm).
bb. Slide control rod guide (6, FIGURE 3-67) with washer (9) in place over end of control rod assembly and
thread into housing finger tight while pushing down on metering valve assembly (48, FIGURE 3-64).
3-116
|
|