ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5P FIGURE 3-98.  Installing Metering Valve aw.    Pull  back  governor  linkage  hook  (46,  FIGURE  3-64),  stretching  spring  (47)  just  enough  to  assemble  hook correctly to fork on governor arm (44).  Position opposite end of hook (46) over pin on arm of metering valve (45), refer to FIGURE 3-99.  Check all governor parts for freedom of movement. FIGURE 3-99.  Installing Governor Linkage ax.  Ensure bushing (10, FIGURE 3-67) on control rod assembly (5) is against control spring guide on control rod. ay.  If removed, thread spring (42, FIGURE 3-64) on tab of governor arm (44). az.  Thread piston assembly (43) on loose end of spring (42). ba.  From inside pump housing (84), install control rod assembly through threaded hole. NOTE Tighten 70 to 80 in-lbs (8 to 9 Nm). bb.  Slide control rod guide (6, FIGURE 3-67) with washer (9) in place over end of control rod assembly and thread into housing finger tight while pushing down on metering valve assembly (48, FIGURE 3-64). 3-116


 