ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 3-29.2.  Cleaning. Warning Cleaning  solvent  is  flammable  and  toxic  to  eyes,  skin,  and  respiratory  tract.    Skin/eye  protection required.  Avoid repeated/prolonged contact.  Good general ventilation is normally adequate. a. Remove  carbon  stop  seal  (6,  FIGURE  3-112)  and  upper  sealing  washer  (7),  using  a  needlenose  pliers. Discard seal and washer. FIGURE 3-112.  Fuel Injection Nozzle b. Suspend nozzles (so carbon stop seal groove is just covered) in cleaning solvent for a few minutes. CAUTION Do not scrape or disturb teflon coating on nozzle body above carbon stop seal groove.   This coating will become discolored during normal operation, but this is not harmful.  Do not use a motor-driven brush to clean nozzle body. c. After soaking, clean tip with a nylon brush. 3-133


 