ARMY TM 9-2815-25624 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 (5) Using driver (JD286), install bushing (12) in connecting rod (4).  If required, hone bushing to obtain piston .  pin clearance of 0.0008 to 0.0024 inch (0.02 to 0.06 mm). 3-46.3    Engine Block. Warning Cleaning  solvent  is  flammable  and  toxic  to  eyes,  skin,  and  respiratory  tract.    Skin/eye  protection required.  Avoid repeated/prolonged contact.  Good general ventilation is normally adequate. Warning Compressed air used for cleaning can create airborne particles that can enter the eyes.  Pressure will not exceed 30 psig (207 kPa).  Eye protection required. a. Inspect and clean engine block as follows: NOTE All components (including piston cooling nozzles, soft plugs, and oil gallery plugs) must be removed from the cylinder block for inspection and cleaning. (1) Inspect each piston cooling nozzle (1, FIGURE 3-155) to make sure it is not plugged or damaged.  Cooling nozzles deliver approximately 0.4 gallon per min (1.50 liters/min) oil flow. FIGURE 3-155.  Inspecting piston Cooling Nozzles (2) Use  a  soft  wire  and  compressed  air  to  clean  nozzle.    Replace  if  condition  is  questionable,  refer  to paragraph 3-48.2.b. 3-204


 