ARMY TM 9-2815-256-24
AIR FORCE TO 38G1-96-2
MARINE CORPS TM 2815-24/5P
Table 3-2. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Test for defective battery charging alternator.
a.
Inspect and test battery charging alternator. Refer to paragraph 3-11.1. If alternator not defective,
do step 3.
b.
Repair or replace battery charging alternator. Refer to paragraph 3-11.
Step 3.
Check for breaks or loose connections in charging circuit.
If breaks or loose connections are found, repair charging circuit. Refer to end item maintenance
manual.
18. BATTERY CHARGE AMMETER SHOWS EXCESSIVE CHARGING AFTER PROLONGED PERIOD.
Step 1.
Check for defective batteries.
a.
Test batteries. Refer to end item maintenance manual. If batteries not defective, do step 2.
b.
Replace batteries. Refer to end item maintenance manual.
Step 2.
Test for defective battery charging alternator.
a.
Inspect and test battery charging alternator. Refer to paragraph 3-11.1. If alternator not defective,
do step 3.
b.
Repair or replace battery charging alternator. Refer to paragraph 3-11.
Step 3.
Check for short in charging circuit.
If shorted, repair charging circuit. Refer to end item maintenance manual.
3-14
|
|