ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 c. Position alternator adjusting strap (3) and secure with capscrew (1), washer (6), and new lockwasher (2).  Tighten capscrew to 35 ft-lbs (47 Nm). d. Install fan and spacer, refer to end item maintenance manual. e. Install fan drive belts, refer to end item maintenance manual. f. Install by-pass hose on water pump and secure with a hose clamp. g. Install  two  oil  cooler  hoses  (2,  FIGURE  3-3)  and  secure  to  water  pump  and  engine  oil  cooler  with  four  hose clamps (1).  Install clamp (5) with screw (3) and washer (4). h. Install inlet hose on pump inlet and secure with a hose clamp. NOTE Air must be expelled from system when system is refilled.  Loosen temperature sending unit fitting at  rear  of  cylinder  head  or  plug  in  thermostat  housing  to  allow  air  to  escape  when  filling  system. Retighten fitting or plug when all the air has been expelled. i. Service coolant system, refer to end item maintenance manual. Change 3 3-26


 