Custom Search
 
  
 
ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 FIGURE 3-33.  Growler Test b. Set multimeter for ohms and touch one probe to a commutator segment and other one to armature core, refer to FIGURE 3-34.  There should be no continuity.  If there is continuity, armature is grounded.  Replace armature if grounded. FIGURE 3-34.  Testing for Grounded Windings c. Set multimeter for ohms and touch probes to two segments, refer to FIGURE 3-35.  There should be continuity at any point.  If there is no continuity, winding is open circuited.  Replace the armature if open circuited. FIGURE 3-35.  Checking for Open Circuit Windings d. Set multimeter for ohms and touch one probe to positive brush holder plate and other one to the holder plate, refer to FIGURE 3-36.  There should be no continuity.  If there is continuity, replace brush holder. 3-47


 