ARMY TM 9-2815-257-24
AIR FORCE TO 38G1-128-2
MARINE CORPS TM 10155A/2815-24/3
3-14
Section VI. UNIT MAINTENANCE PROCEDURES
3-12. RECOIL STARTER ASSEMBLY MAINTENANCE
This task covers removal, cleaning, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
None
(Item 2, App. B, Sect. III)
Parts/Materials:
Solvent, Dry Cleaning (Item 7, App. E)
Rag, Cleaning (Item 8, App. E)
A. REMOVAL.
1.
Remove recoil starter assembly (1, Figure 3-2)
from flywheel housing (2) by removing four
screws (3).
2.
Remove plunger (5) from cylinder block by
removing three screws (6).
B. CLEANING.
Cleaning solvents are flammable and toxic to eye,
skin, and respiratory tract. Skin and eye
protections are required when working in contact
with cleaning solvents. Avoid repeated or
prolonged contact. Work in well ventilated area
only. Keep away from heat, sparks, and open
flame. Do not smoke while using cleaning
solvent. Failure to observe this warning can
result in injury or death to personnel.
Figure 3-2. Recoil Starter Removal
Clean components with cleaning solvent and a
clean rag. Allow to air dry.
WARNING
|
|